TAILIEUCHUNG - Báo cáo y học: "Re-inspiration of CO2 from ventilator circuit: effects of circuit flushing and aspiration of dead space up to high respiratory rate"

Tuyển tập các báo cáo nghiên cứu về y học được đăng trên tạp chí y học quốc tế cung cấp cho các bạn kiến thức về ngành y đề tài: Re-inspiration of CO2 from ventilator circuit: effects of circuit flushing and aspiration of dead space up to high respiratory rate. | De Robertis et al. Critical Care 2010 14 R73 http content 14 2 R73 c CRITICAL CARE RESEARCH Open Access Re-inspiration of CO2 from ventilator circuit effects of circuit flushing and aspiration of dead space up to high respiratory rate Edoardo De Robertis 2 Leif Uttman1 and Bjorn Jonson1 Abstract Introduction Dead space negatively influences carbon dioxide CO2 elimination particularly at high respiratory rates RR used at low tidal volume ventilation in acute respiratory distress syndrome ARDS . Aspiration of dead space ASPIDS a known method for dead space reduction comprises two mechanisms activated during late expiration aspiration of gas from the tip of the tracheal tube and gas injection through the inspiratory line - circuit flushing. The objective was to study the efficiency of circuit flushing alone and of ASPIDS at wide combinations of RR and tidal volume VT in anaesthetized pigs. The hypothesis was tested that circuit flushing and ASPIDS are particularly efficient at high RR. Methods In Part 1 of the study RR and VT were with a computer-controlled ventilator modified for one breath at a time without changing minute ventilation. Proximal dead space in a y-piece and ventilator tubing VDaw prox was measured. In part two changes in CO2 partial pressure PaCO2 during prolonged periods of circuit flushing and ASPIDS were studied at RR 20 40 and 60 minutes-1. Results In Part 1 VDaw prox was of VT at RR 10 minutes-1 and 16 at RR 60 minutes-1. In Part 2 circuit flushing reduced PaCO2 by 20 at RR 40 minutes-1 and by 26 at RR 60 minutes-1. ASPIDS reduced PaCO2 by 33 at RR 40 minutes-1 and by 41 at RR 60 minutes-1. Conclusions At high RR re-breathing of CO2 from the y-piece and tubing becomes important. Circuit flushing and ASPIDS which significantly reduce tubing dead space and PaCO2 merit further clinical studies. Introduction In acute respiratory distress syndrome severe obstructive lung disease and at increased intracranial pressure it may be

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.