TAILIEUCHUNG - Newnes Sensor Technology Handbook 2005 Yyepg Lotb Part 6

Tham khảo tài liệu 'newnes sensor technology handbook 2005 yyepg lotb part 6', kỹ thuật - công nghệ, cơ khí - chế tạo máy phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | Chapter 7 CHEMFETs Another method for chemical detection in solutions or in gas relies on the charge transfer that can occur during a chemical reaction on a surface. In these devices the surface of interest is a metal electrode which is actually the exposed gate of a field effect transistor FET . Since the conduction from source to drain in a FET is modified by charge on the gate this device can be a remarkably sensitive detector of certain absorbed species. These sensors are called CHEMFETs. Of course to build a selective detector it is necessary to select a metal electrode that allows only one chemical reaction to occur. Simple metals are not very selective so simple CHEMFETs suffer from a lack of selectivity meaning that they respond to many different chemical species. One way to improve the selectivity of such a sensor is to follow a biological example and to coat the electrode with molecules that are indeed very selective. Antibodies are molecules that tend to react only with a particular virus molecule and are more chemically selective than any simple metal electrode. Finally there are a number of medical applications that rely on detection of oxygen in the bloodstream. Unfortunately the bloodstream is a difficult place to work because white blood cells interpret the presence of almost any foreign matter as an invading organism and tend to form scabs on all surfaces of such objects. Blood does exhibit a detectable change in color upon the absorption of oxygen and blood oxygen may be crudely measured by looking at blood color. For example a sensor that measures blood reflectivity at 700 nm and at 800 nm ought to be able to measure the blood oxygen content very accurately. The measurement at 800 nm is used to cancel out effects of scab overcoating. One possible implementation is a fiber-optic system that transmits light of two colors 700 and 800 nm and senses the reflected light intensity as a measure of blood oxygen. Such a system is often used during surgical

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.