TAILIEUCHUNG - Biosensors Emerging Materials and Applications Part 7

Tham khảo tài liệu 'biosensors emerging materials and applications part 7', kỹ thuật - công nghệ, cơ khí - chế tạo máy phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | 232 Biosensors - Emerging Materials and Applications Of these two types of single aptamer-based B F separation systems the first can be easily designed because it does not require any additional sequences whereas the second system requires careful design of the additional sequence of the aptamer with structural prediction. However the benefit of the second system is that it can eliminate many interfering compounds. The first system can eliminate enzyme-modified aptamers that do not bind to the target molecule but it is difficult to eliminate interfering compounds because aptamers that bind to the target molecule are present in the supernatant. It is therefore necessary to select a particular system to suit the needs of each particular target molecule. Wei et al. reported a different type of single aptamer based B F separation system without complementary DNA being present Wei Ho 2009 . They utilized steric hindrance between enzyme-modified antibodies and antigen-modified target-binding aptamers. They used fluorescein-modified aptamers and anti-fluorescein horseradish peroxidase HRP -conjugated antibody. The antibody cannot bind to the fluorescein-modified aptamer due to steric hindrance without its target molecule. The aptamers change conformation upon binding to the target molecule and then the antibodies can bind to them. Since the aptamers were immobilized on the solid support this sensing system enabled B F separation to occur using an aptamer. Homogeneous sensing To measure the target molecules without B F separation regulation of signal output is required. Jhaveri et al. reported aptamers that changed their structure upon binding to the target molecule which resulted in the regulation of fluorescent signals Jhaveri et al. 2000 . If we can introduce enzyme signal amplification into a signaling aptamer a highly sensitive detection can be performed without the need for B F separation. Reported homogeneous detection systems using enzymes are based on two .

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.