TAILIEUCHUNG - HANDBOOK OF CARDIAC PACING – PART 9

Gần và tín hiệu trường xa. Các nhóm đầu tiên của khu phức hợp được ghi nhận giữa các cuộn dây sốc xa và trường hợp các máy khử rung tim. Đây được gọi là "xa", vì họ là xa với cảm biến điện cực trong não thất. Nhóm thứ hai của khu phức hợp được ghi lại từ các điện cực cảm biến bên trong tâm thất phải. | 120 Handbook of Cardiac Pacing 13 Fig. . Near and far field signals. The first group of complexes are recorded between the distal shock coil and the defibrillator case. These are referred to as far field because they are distant to the intraventricular sensing electrodes. The second group of complexes are recorded from the sensing electrodes within the right ventricle. These are referred to as near field . Fig. . Atrial and ventricular intracardiac signals. This is a tracing from a patient in ventricular tachycardia. The top tracing is an intracardiac atrial electrogram with a sinus rate of around 105 bpm. The bottom trace is an intracardiac ventricular electrogram showing a rate of 200 bpm. This is classic AV dissociation with the ventricle going faster than the atrium and is diagnostic of ventricular tachycardia. It rules out atrial fibrillation atrial flutter or supraventricular tachycardia as the cause for the rapid ventricular rate. Basic Concepts of Implantable Cardioverter Defibrillators 121 MAGNET RESPONSE OF THE ICD ICDs have a very different response to magnet application than do pacemakers. In addition the effect of sustained magnet application may differ from one device to another and may even be programmable as to the effect of the magnet. There is one feature that is constant across all ICDs with magnet application which is the suspension of tachycardia therapy. If a patient is receiving inappropriate shocks or if for any reason suspending therapy becomes necessary placing a ring type pacemaker magnet over the ICD will immediately prevent further therapy from being delivered. Some devices can be programmed to the off setting by keeping the magnet in place for 30 seconds. The latter type of device can be turned back on by placing the magnet over it for 30 seconds as well. Others will immediately resume detection and therapy when the magnet is removed no matter how long the magnet has been applied. This is a useful feature when a programmer is

TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.