TAILIEUCHUNG - Wind Farm Impact in Power System and Alternatives to Improve the Integration Part 3

Tham khảo tài liệu 'wind farm impact in power system and alternatives to improve the integration part 3', kỹ thuật - công nghệ, cơ khí - chế tạo máy phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | Wind Power Integration Network Issues 39 Test case IEEE 30 bus system is used as a test system for the voltage stability analysis and it will be the test system for this section as well. Bus 30 is chosen for application of the proposed method because it is the weakest bus of this system and WFs are usually connected at remote areas where the network is weak. The method can however be applied at any other bus. At the base case active power load at bus 30 is MW pu and the reactive power is MVAr pu . The higher voltage solution VH VL and Thevenin equivalent are the same as in sec. . A capability chart is drawn Fig. 13 with the load at node 30 marked by a diamond. The load point lies well within the allowable area with all the constraints satisfied. The accuracy of the capability chart can be further tested in many different ways. A second way is to evaluate the corners of the feasible region points A B C D E F and G of Fig. 13. Each corner is the intersection of two constraints that are about to be violated. The active and reactive power coordinates of the corner points are used as P and Q injections at bus 30 and a detailed load flow study is carried out using DIgSILENT Power Factory software. The results are listed in Table 1 which identifies the corner points the corresponding power injections the limiting constraints and the values obtained from load flow calculations for the voltage and current at bus 30. Threshold values for the constraints are shown within brackets following the first incident of each constraint. Examining the first row of the table for corner point A the voltage at node 30 is pu exceeding the maximum allowable voltage PG is pu which is less than PGirúrứ I and QG are both within limits. The same validation can be observed for all other corner points with an error less than 2 . Fig. 13. The capability charts for bus 30 of the IEEE 30 bus system 40 Wind Farm - Impact in Power System and Alternatives to .

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.