TAILIEUCHUNG - Volume 17 - Nondestructive Evaluation and Quality Control Part 4

Tham khảo tài liệu 'volume 17 - nondestructive evaluation and quality control part 4', kỹ thuật - công nghệ, cơ khí - chế tạo máy phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | Fig. 57 Current and flux density curves during demagnetization projected from the hysteresis loop. See text for discussion. In using this principle the magnetizing force must be high enough at the start to overcome the coercive force and to reverse the residual field initially in the part. Also the incremental decrease between successive reductions in current must be small enough so that the reverse magnetizing force will be able on each cycle to reverse the field remaining in the part from the last previous reversal. Demagnetization With Alternating Current. A common method of demagnetizing small to moderate-size parts is by passing them through a coil through which alternating current at line frequency is passing usually 50 to 60 Hz . Alternatively the 60-Hz alternating current is passed through a coil with the part inside the coil and the current is gradually reduced to zero. In the first method the strength of the reversing field is reduced by axially withdrawing the part from the coil or the coil from the part and for some distance beyond the end of the coil or part along that axial line. In the second method gradual decay of the current in the coil accomplishes the same result. Passing a part through an ac coil is usually the faster preferred method. Small parts should not be loaded into baskets and the baskets passed through the coil as a unit because alternating current will not penetrate into such a mass of parts and because only a few parts on the outside edges will be demagnetized and these possibly only partially demagnetized . Small parts can be demagnetized in multiple lots only if they are placed in a single layer on a tray that holds them apart and in a fixed position with their long axes parallel to the axis of the coil. Large parts are not effectively demagnetized with 60-Hz alternating current because of its inability to penetrate. Alternating current with 25-Hz frequency is more effective. Machines that provide decaying alternating current have

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.