TAILIEUCHUNG - Báo cáo y học: " Computerized two-lead resting ECG analysis for the detection of coronary artery stenosis after coronary revascularization"

Tuyển tập các báo cáo nghiên cứu khoa học ngành y học tạp chí Medical Sciences dành cho các bạn sinh viên ngành y tham khảo đề tài: Computerized two-lead resting ECG analysis for the detection of coronary artery stenosis after coronary revascularization. | Int. J. Med. Sci. 2008 5 50 Research Paper International Journal of Medical Sciences ISSN 1449-1907 2008 5 2 50-61 Ivyspring International Publisher. All rights reserved Computerized two-lead resting ECG analysis for the detection of coronary artery stenosis after coronary revascularization Eberhard Grube1 Andreas Bootsveld2 Lutz Buellesfeld1 Seyrani Yuecel1 Joseph T Shen3 Michael Imhoff4 1. Department of Cardiology and Angiology HELIOS Heart Center Siegburg Siegburg Germany 2. Department of Cardiology Evangelisches Stift St. Martin Koblenz Germany 3. Premier Heart LLC Port Washington NY USA 4. Department for Medical Informatics Biometrics and Epidemiology Ruhr-University Bochum Bochum Germany Correspondence to Michael Imhoff MD PhD Am Pastorenwaldchen 2 D-44229 Dortmund Germany. Phone 49-231-973022-0 Fax 49-231-973022-31 e-mail mike@ Received Accepted Published Background Resting electrocardiogram ECG shows limited sensitivity and specificity for the detection of coronary artery disease CAD where patients with a history of coronary revascularization may pose special challenges. Several methods exist to enhance sensitivity and specificity of resting ECG for diagnosis of CAD but such methods are not better than a specialist s judgement. We compared a new computer-enhanced resting ECG analysis device 3DMP to coronary angiography to evaluate the device s accuracy in detecting hemodynamically relevant CAD. Methods A convenience sample of 172 patients with a history of coronary revascularization scheduled for coronary angiography was evaluated with 3DMP before coronary angiography. 3DMP s sensitivity and specificity in detecting hemodynamically relevant coronary stenosis as diagnosed with coronary angiography were calculated as well as odds 1 ratios for the 3DMP severity score and coronary artery disease risk factors. Results The 3DMP system accurately identified 50 of 55 patients as having hemodynamically .

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.