TAILIEUCHUNG - Developments in Heat Transfer Part 4

Tham khảo tài liệu 'developments in heat transfer part 4', kỹ thuật - công nghệ, cơ khí - chế tạo máy phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | 110 Developments in Heat Transfer modified while that of edge vials is strongly reduced. This is due to the contribution of the tray band which acts as thermal shield for the radiative heat coming from chamber walls. Therefore it must be remarked that during the phase of process development the user has to take into account that the pressure dependence of Kv does not depend only on the type of vials but also on the configuration used for loading the product into the drying chamber. In general the gravimetric procedure gives the best accuracy and robustness even if it is more time demanding with respect to other global methods available. However the use of the pressure rise test technique is strongly suggested in case of industrial apparatus where the gravimetric procedure is not practicable as the intervention of the user to place temperature sensors over the lot of vials is limited. Therefore it has been shown that the pressure rise test technique and in particular the latest developments like the DPE algorithm can be effectively used for measuring the value of Kv whichever is the scale of the equipment without requiring an excessive effort from the users. In addition an estimation of the mean value of Kv is more than enough for an effective description of the heat transfer of the lot as the effect of batch non-uniformity in a manufacturing process is less marked. A further advantage of the pressure rise test technique is that with respect to other global methods like TDLAS it requires no modifications of the equipment and its hardware. A final comment concerns the problem of scale-up or process transfer of a recipe from one unit to another one. It has been proved that the heat transfer coefficient of a specific container can varies significantly mainly for edge vials with the type of equipment used even if the same loading configuration is used. Therefore if this difference is relevant the recipe which is usually developed in laboratory and has to be transferred

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.