TAILIEUCHUNG - Refractive Lens Surgery - part 2

Để đạt được emmetropia trong phẫu thuật ống kính khúc xạ phụ thuộc vào biometry chính xác và tính toán sức mạnh IOL. Immersion siêu âm và giao thoa sự gắn kết một phần chứng minh một mức độ rất cao của sự tương quan xác định chiều dài trục. T | 3 Biometry for Refractive Lens Surgery Mark Packer I. Howard Fine Richard s. Hoffman CORE MESSAGES Achieving emmetropia in refractive lens surgery depends on accurate biometry and IOL power calculation. Immersion ultrasound and partial coherence interferometry demonstrate a very high degree of correlation in determination of axial length. In eyes with a history of keratorefractive surgery keratometry cannot be used to determine the central power of the cornea. Using corneal topography allows accurate determination of corneal power in eyes that have undergone incisional refractive surgery such as radial keratometry. Axial length measurement remains an indispensable technique for intraocular lens IOL power calculation. Recently partial coherence interferometry has emerged as a new modality for biometry 1 . Postoperative results achieved with this modality have been considered analogous to those achieved with the ultrasound immersion technique 2 . Reportedly user-friendly and less dependent on technician expertise than ultrasound methods non-contact optical biometry is however limited by dense media . posterior subcapsular cataract. A second limitation of the optical method is the lack of a lens thickness measurement which is a required variable in the Holladay II IOL power calculation software version . On the other hand according to Holladay the lens thickness can be estimated by the formu la age 100 . Also optical biometry can provide keratometry measurements obviating the need for a second instrument. Immersion ultrasound has long been recognized as an accurate method of axial length measurement generally considered superior to applanation ultrasound techniques 3 4 . The absence of corneal depression as a confounding factor in measurement reduces the risk of inter-technician variability in technique. In addition to having a short learning curve immersion ultrasound has no limitations in terms of media density and measurement capability. On the .

TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.