TAILIEUCHUNG - Báo cáo y học: "Qualitative Dosimetric and Radiobiological Evaluation of High – Dose – Rate Interstitial brachytherapy Implant"

Tuyển tập các báo cáo nghiên cứu khoa học ngành y học tạp chí Medical Sciences dành cho các bạn sinh viên ngành y tham khảo đề tài: Qualitative Dosimetric and Radiobiological Evaluation of High – Dose – Rate Interstitial brachytherapy Implants. | Int. J. Med. Sci. 2008 5 41 Research Paper International Journal of Medical Sciences ISSN 1449-1907 2008 5 1 41-49 Ivyspring International Publisher. All rights reserved Qualitative Dosimetric and Radiobiological Evaluation of High - Dose -Rate Interstitial brachytherapy Implants Than S. Kehwar1 Syed F. Akber2 and Kamlesh Passi 3 1. Department of Radiation Oncology University of Pittsburgh Cancer Institute Pittsburgh PA USA. 2. Department of Radiation Oncology Case Western Reserve University Cleveland OH USA 3. Department of Radiation Oncology MD Oswal Memorial Cancer treatment and Research Center Ludhiana Pb India. Correspondence to T. S. Kehwar . DABR Department of Radiation Oncology University of Pittsburgh Cancer Institute Robert E. Eberly Pavilion UPMC Cancer Center 51 Brewer Drive Uniontown PA 15401. Phone 724 437 2503 Fax 724 437 8846 Email drkehwar@ Received Accepted Published Radiation quality indices QI tumor control probability TCP and normal tissue complication probability NTCP were evaluated for ideal single and double plane HDR interstitial implants. In the analysis geometrically-optimized at volume GOV treatment plans were generated for different values of inter-source-spacing ISS within the catheter inter-catheter-spacing ICS and inter-plane-spacing IPS for single - and double - plane implants. The dose volume histograms DVH were generated for each plan and thecoverage volumes of 100 150 and 200 were obtained to calculate QIs tCp and NTCP. Formulae for biologically effective equivalent uniform dose BEEUD for tumor and normal tissues were derived to calculate TCP and NtCP. Optimal values of QIs except external volume index EI and TCP were obtained at ISS cm and ICS cm for single-plane implants and ISS cm ICS cm and IPS to cm for double - plane implants. From this study it is assessed that ISS cm ICS cm for single - plane implant and IPS between cm to .

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.