TAILIEUCHUNG - Refractive Lens Surgery (part 2)

Bệnh nhân được đặt ở một vị trí ngồi trong một chiếc ghế trong phòng kiểm tra với người đứng đầu reclined nhẹ nhàng chống lại tựa đầu. Trung bình "Tổng chiều dài" báo cáo của đơn vị đã được nhập vào công thức tính điện II Holladay IOL. Đối với Thạc sĩ IOL, chiều dài trục được lựa chọn với tỷ lệ tín hiệu-to-noise cao nhất đã được sử dụng làm cơ sở để so sánh. | 12 M. Packer . Fine . Hoffman IOL Master Zeiss Humphrey Systems Jena Germany with measurements obtained by immersion ultrasound using the Axis II Quantel Medical Clermont-Ferrand France . We have also examined the postoperative refractions of patients undergoing cataract extraction with posterior chamber IOL implantation to determine the accuracy of the immersion ultrasound technique. Fifty cataractous eyes underwent preoperative axial length measurement with both the Axis II and the IOL Master. For the Axis II immersion technique the Praeger shell was employed. Patients were placed in a sitting position in an examination room chair with the head reclined gently against the headrest. The average Total Length reported by the unit was entered into the Holladay II IOL power calculation formula. For the IOL Master the selected axial length with the highest signal-to-noise ratio was used as the basis for comparison. The measured axial lengths were plotted and a linear regression trendline fitted to the data. The Pearson correlation coefficient was determined to assess the relationship between the immersion and the optical measurements according to the formula ọ 1 1-n S x - p s y - p s . Keratometry was performed with the IOL Master. The three reported sets of values were compared for consistency and correlated with the axis and magnitude of the eye s preoperative astigmatism. Either an averaged value of three measurements or of the two closest measurements in case one measurement appeared to be an outlier was entered into the formula. In selected cases autoker-atometry HARK 599 Zeiss Humphrey Systems Jena and or computerized corneal topography EyeSys Technologies Houston were utilized to delineate better the preoperative keratometry. The corneal white-to-white diameter was determined with the Holladay-Godwin Corneal Gauge. One surgeon IHF performed all surgery. The Holladay II IOL power calculation formula was used to select the intraocular lens for implantation .

TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.