TAILIEUCHUNG - Power Quality Harmonics Analysis and Real Measurements Data Part 15

Tham khảo tài liệu 'power quality harmonics analysis and real measurements data part 15', kỹ thuật - công nghệ, cơ khí - chế tạo máy phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | Harmonic Distortion in Renewable Energy Systems Capacitive Couplings 269 Fig. 6a shows the fixed-speed wind turbine with asynchronous squirrel cage induction generator SCIG directly connected to the grid via transformer. Fig. 6b represents the limited variable speed wind turbine with a wound rotor induction generator and partial scale frequency converter on the rotor circuit known as doubly fed induction generator DFIG . Fig. 6c shows the full variable speed wind turbine with the generator connected to the grid through a full-scale frequency converter. These power electronic interfaces are rated as a percentage of the machine power hence larger systems are accountable for higher distortions. Recent investigations based on wind energy systems suggests that frequency converters with a typical pulse width modulated with kHz of switching frequency can in fact cause harmonics in the line current leading to harmonic voltages in the network Conroy Watson 2009 . Moreover most simplified models of wind farms consider a simple series impedance model for underground cables that connect wind turbines with the network grid. Thus capacitive couplings with ground through cables are not considered for different frequencies components. To simulate wind farms harmonic distortion behaviour accurately it is important to model cables by their frequency dependent model. The equivalent circuit for the capacitive coupling model of wind farms is shown in Fig. 7. Fig. 7. Capacitive coupling model for wind farm. Notice that otherwise the capacitive model of solar installations the wind turbine is directly connected to the rectifier side of the converter. The capacitive coupling seen by the DC bus through the wind turbine is composed of the path between the rectifier side and ground because of the high harmonic current component imposed by the switching actions whereas the capacitive coupling seen through the grid is represented by the inverter side the filter and the underground cable. .

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.