TAILIEUCHUNG - Intelligent and Biosensors 2012 Part 7

Tham khảo tài liệu 'intelligent and biosensors 2012 part 7', kỹ thuật - công nghệ, cơ khí - chế tạo máy phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | Non-invasive Electronic Biosensor Circuits and Systems 141 our increasingly sedentary and overweight society. We are currently assessing the system for EEG recordings in particular for as a BCI device that would greatly assist the severely disabled and it may also be of use in epilepsy monitoring being able to track movement and record EEG in a comfortable environment. 6. Future researches Currently our researches are focused on exploring all the possible uses of the proposed biomedical sensing system particularly in athlete and long term patient monitoring and BCIs. Physical activity monitoring Currently our research in physical activity monitoring is still focused on clinical assessment of human performance for long term monitoring particularly for full body assessment. It is well known that rapid changes in body orientation such as during a free fall may be identified from the information gathered by the accelerometer. Figure 14 shows an example using data recorded using our device. Moreover being able to detect rapid changes in body orientation provides useful information for syncope detection geriatric care and sport science. In this evaluation the prototype was attached to the subject s chest using an elastic band with embedded dry electrodes. Our device was configured to acquire one EKG channel a signal from the light reflected PPG Photo PletysmoGraphic unit and skin temperature not shown . The top section of Figure 14 shows the posture assessment gathered from the accelerometer during a passage from a lying down face up to a standing position. The lower section of Figure 11 shows the event related biological signals . ECG 1st lead top trace and PPG signals bottom trace . The passage from a lying position to a standing will cause a large blood pressure gradient inside the body a vasovagal reaction and this could be a cause for a syncope attack Benditt Ferguson et al. 1996 . Fig. 14. Posture assessment accelerometer signals 142 Intelligent and .

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.