TAILIEUCHUNG - Cấy ghép các khớp ngón tay

Giả thay thế trong tay phải giải quyết những thách thức độc đáo như bảo quản như tài sản thế chấp của các dây chằng, gân cân bằng, và tính ổn định. Một số arthroplasty cấy Gần đây phát triển của metacarpophalangeal và gần khớp interphalangeal có giải phẫu Thiết kế các thành phần khớp; | Perspectives on Modern Orthopaedics New-Generation Implant Arthroplasties of the Finger Joints Peter M. Murray MD Abstract Prosthetic replacement in the hand must address such unique challenges as preservation of the collateral ligaments tendon balancing and stability. Some recently developed implant arthroplasties of the metacarpophalangeal and proximal inter-phalangeal joints have anatomically designed articular components others have noncemented press- t carefully contoured intramedullary stems. The rationale behind developing the unlinked or semiconstrained prosthesis with anatomic geometry is that it would create balanced forces across the joint. Low-pro le anatomically designed implants limit the amount of bone removed and preserve the integrity of the collateral ligaments. A metacarpophalangeal joint implant with an elliptical metacarpal head and a non xed center of rotation can enhance stability in Hexion through greater articular contact. A proximal interphalangeal joint implant that preserves the collateral ligaments also can achieve improved stability. Component loosening is not an early complication with these recent designs and arc of motion is satisfactory. J Am Acad Orthop Surg 2003 11 295-301 The primary goals of finger joint arthroplasty are to alleviate pain restore stability and preserve or enhance motion. Early digital implants such as the Vitallium cap for arthroplasty of the metacarpophalangeal MCP and proximal interphalangeal PIP joints 1 were developed with concepts similar to those used in successful implant arthroplasty of the lower extremity. However finger total joint arthroplasty has been slow to develop primarily because of early design failures. The Swanson hinged Silastic spacer is the most commonly used implant for PIP and MCP joint reconstruction particularly for patients with rheumatoid arthritis in whom 90 10-year survivorship has been 3 In 1959 Brannon and Klein1 published the results of the first series of a digital

TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.