TAILIEUCHUNG - Báo cáo y học: "Arterial pressure-based cardiac output in septic patients: different accuracy of pulse contour and uncalibrated pressure waveform devices"

Tuyển tập các báo cáo nghiên cứu về y học được đăng trên tạp chí y học quốc tế cung cấp cho các bạn kiến thức về ngành y đề tài: Arterial pressure-based cardiac output in septic patients: different accuracy of pulse contour and uncalibrated pressure waveform devices. | Mon net et al. Critical Care 2010 14 R109 http content 14 3 R109 c CRITICAL CARE RESEARCH Open Access Arterial pressure-based cardiac output in septic patients different accuracy of pulse contour and uncalibrated pressure waveform devices Xavier Monnet 1 2 Nadia Anguel1 2 Brice Naudin1 2 Julien Jabot1 2 Christian Richard1 2 and Jean-Louis Teboul1 2 Abstract Introduction We compared the ability of two devices estimating cardiac output from arterial pressure-curve analysis to track the changes in cardiac output measured with transpulmonary thermodilution induced by volume expansion and norepinephrine in sepsis patients. Methods In 80 patients with septic circulatory failure we administered volume expansion 40 patients or introduced increased norepinephrine 40 patients . We measured the pulse contour-derived cardiac index CI provided by the PiCCO device CIpc the arterial pressure waveform-derived CI provided by the Vigileo device CIpw and the transpulmonary thermodilution CI CItd before and after therapeutic interventions. Results The changes in CIpc accurately tracked the changes in CItd induced by volume expansion bias L min m2 as well as by norepinephrine bias L min m2 . The changes in CIpc accurately detected an increase in CItd 15 induced by volume expansion and norepinephrine introduction increase area under ROC curves to and to respectively P versus for both . The changes in CIpw were less reliable for tracking the volume-induced changes in CItd bias L min m2 and norepinephrine-induced changes in CItd bias L min m2 . The changes in CIpw were unable to detect an increase in CItd 15 induced by volume expansion and norepinephrine introduction increase area under ROC curves to and to respectively both not significantly different from versus . Conclusions The CIpc was reliable and accurate for assessing the CI changes .

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.