TAILIEUCHUNG - Standard Handbook for Mechanical Engineers 2010 Part 17

Tham khảo tài liệu 'standard handbook for mechanical engineers 2010 part 17', kỹ thuật - công nghệ, cơ khí - chế tạo máy phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | 19-20 MECHANICAL REFRIGERATION The double-pipe cooler is usually of 2-in 50-mm inner or brine-flow pipe and 3-in 75-mm outer pipe. The commercial rating is 15 to 20 ft 5 to 6 m length of coil per ton of refrigeration. The shell-and-tube cooler is used with closed heads and is erected both vertically and horizontally brine flows through the tubes and ammonia is in the shell. It is made in sizes from 1 to 350 tons with ratings of 8 to 15 ft2 effective surface per ton varying with the temperature and brine velocities tubes 1 to 21 2 in 25 to 63 mm arranged multipass. This type of cooler has largely displaced all other types in recent installations Table . REFRIGERANT PIPING See also Sec. 8. It is important to the proper operation of a refrigeration system that the piping or mains interconnecting the compressors condensers evaporators and receivers be properly sized. This piping must be considered in three categories viz. liquid lines suction lines and discharge lines. Essentially pipeline sizing is governed by pressure drop first cost operating cost noise and oil entrainment. Excessive pressure drops penalize compressor efficiencies and may affect control-valve operation adversely. Liquid-line velocities for most refrigerants are in the order of 60 to 400 ft min to 22 m s suction lines from 700 to 4 600 ft min 38 to 250 m s and discharge lines from 1 000 to 5 000 ft min 55 to 275 m s . Pressure drops vary approximately as the square of the velocity or tonnage and directly as the length of the piping. For liquid lines when evaporator is located above condenser the following pressure drops in pounds per square inch per foot kilopascals per meter of static lift should be allowed ammonia R 12 R 22 R 11 . See alsoSecs. 3 and 4. Ammonia Mains For the average installation Table shows the maximum tons of refrigeration normally allowed for various sizes of standard pipe based on 100 ft 30 m equivalent length of piping

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.