TAILIEUCHUNG - torque control Part 10

Tham khảo tài liệu 'torque control part 10', kỹ thuật - công nghệ, cơ khí - chế tạo máy phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | 170 Torque Control From this equation it can be seen that for constant stator flux amplitude and flux produced by the permanent magnet the electromagnetic torque can be changed by control of the torque angle. The torque angle s can be changed by changing position of the stator flux vector with respect to the PM vector using the actual voltage vector supplied by the PWM inverter Dariusz 2002 . The flux and torque values can be calculated as in Section or may be estimated as in Section . The internal flux calculator is shown in Fig. 24. Fig. 24. Flux Estimator Block Diagram The internal structure of the predictive controller is in Fig. 25. Fig. 25. Predictive Controller Sampled torque error ATe and reference stator flux amplitude ỵpsref are delivered to the predictive controller. The error in the torque is passed to PI controller to generate the increment in the load angle AS required to minimize the instantaneous error between reference torque and actual torque value. The reference values of the stator voltage vector are calculated as V _ref2 _ref2 and rf tan-1 18 VsD _ ref Where . r. s . s 19 Ts _ f v f AS RsisQ 20 T Where Ts is the sampling period. For constant flux operation region the reference value of stator flux amplitude is equal to the flux amplitude produced by the permanent magnet. So normally the reference value of the stator flux is considered to be equal to the permanent magnet flux. Torque Control of PMSM and Associated Harmonic Ripples 171 Implementation of SVMDTC The described system in Fig. 23 has been implemented in Matlab Simulink with the same data and loading condition as in HDTC with PI controllers setting as Predictive Controller Ki Kp 1 Speed Controller Ki 1 Kp . The simulation results are shown in Fig. 26 to Fig. 29. As evidence from the figures the SVM-DTC guarantee lower current pulsation smooth speed as well as lower torque pulsation. This is mainly due to the fact that the inverter switching in .

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.