TAILIEUCHUNG - Pediatric PET Imaging - part 2

Năng lượng phát ra từ khí thải thứ i của các hạt nhân phóng xạ trong cơ quan nguồn là một sản phẩm của các phóng xạ hấp thụ cân bằng hằng số liều, Di, và tích lũy, Ã. Nếu một vị phóng xạ gửi trong bộ phận nguồn có nhiều khí thải, liều lượng cân bằng hấp thụ liên tục nên được tính cho mỗi phát thải và summated. | 40 Chapter 4 Dosage of Radiopharmaceuticals and Internal Dosimetry and frequency of each emission of the radionuclide are known. If we designate Ei as the energy of the ith emission ni is the frequency of that emission. The amount of radiation energy emitted per unit of accumulated radioactivity can then be described as Ai 6 where Ei is in MeV and Di is in g-rad pCi-hr . Di is defined as equilibrium absorbed dose constant of the ith emitter. The energy emitted from the ith emission of the radionuclide in the source organ is a product of the equilibrium absorbed dose constant Ai and accumulated radioactivity Ã. If a radionuclide deposited in the source organ has more than one emission the equilibrium absorbed dose constant should be calculated for each emission and summated. Total Energy Absorbed by Target Organ D Due to the distance and attenuation between the source organ and target oranges only a fraction of the energy emitted by the source organ is absorbed by the target organ. This fraction factor needs to be quantified so that the total absorbed dose by the target organ can be estimated. Absorbed Fraction f The absorbed fraction depends on the geometric relationship of the source and target organ the emission energy of the radionuclide and the composition of the source organs the target organ and those organs in between. Mathematically the absorbed fraction of the ith emission of the radionuclide can be expressed as fi tk Sj . The energy absorbed by the target organ tk from the ith emission of the radionuclide in source organ Sj is equal to Ãjfi tk Sj Ai. So the total energy absorbed by target organ tk from all emissions in the source organ sj is Energy Absorbed g - rad Aj Xfi tk Sj Ai. 7 i Because the absorbed dose is defined as energy absorbed in unit mass the dose delivered from the source organ sj to the target organ tk is z I A D tk Sj rad I Xf i tk Sj A i I m-k i 8 where Ãj is the cumulated activity in source organ Sj and mk is the mass of the .

TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.