TAILIEUCHUNG - 1999 HVAC Applications Part 7

Tham khảo tài liệu '1999 hvac applications part 7', kỹ thuật - công nghệ, cơ khí - chế tạo máy phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | Industrial Local Exhaust Systems Q 2gR x q v p1 ỵ3 20 ypcp where QO volumetric flow rate m3 s g gravitational acceleration m s2 R air gas constant 287 J kg-K p local atmospheric pressure Pa cp constant pressure specific heat for air 1004 J kg -K qconv convection heat transfer rate W L vertical height of hot object m Ap cross-sectional area of airstream at upper limit of hot body m2 For a standard atmospheric pressure of kPa Equation 20 can be written as 9 1 3 Qo qConvLAp 21 For three-dimensional bodies the area Ap in Equations 20 and 21 is approximated by the plan view area of the hot body Figure 19A . For horizontal cylinders Ap is the product of the length and the diameter of the rod. For vertical surfaces the area Ap in Equations 20 and 21 is the area of the airstream viewed from above as the flow leaves the vertical surface Figure 19B . As the airstream moves upward on a vertical surface it appears to expand at an angle of approximately 4 to 5 . Thus Ap is given by Ap wL tan 0 22 where w width of vertical surface m L height of vertical surface m 0 angle of air stream expansion For horizontal heated surfaces Ap is the surface area of the heated surface and L is the longest length conservative of the horizontal surface or its diameter if it is round Figure 19C . If the heat transfer is caused by steam from a hot water tank q . hfgGAp 23 where qconv convective heat transfer kW hfg latent heat of vaporization kJ kg G steam generation rate kg s -m2 Ap surface area of the tank m2 Fig. 18 Influence of Hood Location on Contamination of Air in the Operator s Breathing Zone At 100 C the latent heat of vaporization is 2257 kJ kg. Using this value and Equation 23 Equation 20 simplifies to 1 3 Qo 5Ap GL 17 3 24 The exhaust volumetric flow rate determined by Equation 20 or 24 is the required exhaust flow rate when 1 a low canopy hood of the same dimensions as the hot object or surface is used and 2 side and back baffles are used to prevent room air .

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.