TAILIEUCHUNG - 1999 HVAC Applications Part 4

Tham khảo tài liệu '1999 hvac applications part 4', kỹ thuật - công nghệ, cơ khí - chế tạo máy phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | 1999 ASHRAE Applications Handbook SI Nonunidirectional airflow may provide satisfactory contamination control results for cleanliness levels of Class through Class . Attainment of desired cleanliness classes with designs similar to Figures 2 and 3 presupposes that the major space contamination is from makeup air and that contamination is removed in air-handler or ductwork filter housings or through HEPA filter supply devices. When internally generated particles are of primary concern clean workstations are provided in the clean space. Air turbulence is harmful for flow control but air turbulence is needed to enhance the mixing of low and high particle room concentrations and produce a homogeneous particle concentration level acceptable to the process. Unidirectional Airflow Air patterns are optimized and air turbulence is minimized in unidirectional airflow. In a vertical laminar flow VLF room air is typically introduced through the ceiling HEPA or ULPA filters and returned through a raised access floor or at the base of sidewalls. Because air enters from the entire ceiling area this configuration produces nominally parallel airflow. In a horizontal flow cleanroom air enters one wall and returns on the opposite wall. A downflow cleanroom has a ceiling with HEPA filters but air flows from only a portion of the ceiling. In a cleanroom with a low class number the greater part of the ceiling requires HEPA filters. For an ISO Class 5 or better room the entire ceiling usually requires HEPA filtration. Ideally a grated or perforated floor serves as the air exhaust. This type of floor is inappropriate in pharmaceutical cleanrooms which typically have solid floors and low-level wall returns. In a downflow cleanroom a uniform shower of air bathes the entire room in a downward flow of ultraclean air. Contamination generated in the space will not move laterally against the downward flow of air it is swept down and out through the floor or contribute to a buildup

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.