TAILIEUCHUNG - báo cáo khoa học: "IsoBED: a tool for automatic calculation of biologically equivalent fractionation schedules in radiotherapy using IMRT with a simultaneous integrated boost (SIB) technique"

Tuyển tập báo cáo các nghiên cứu khoa học quốc tế ngành y học dành cho các bạn tham khảo đề tài: IsoBED: a tool for automatic calculation of biologically equivalent fractionation schedules in radiotherapy using IMRT with a simultaneous integrated boost (SIB) technique | Bruzzaniti et al. Journal of Experimental Clinical Cancer Research 2011 30 52 http content 30 1 52 Journal of Experimental Clinical Cancer Research RESEARCH Open Access IsoBED a tool for automatic calculation of biologically equivalent fractionation schedules in radiotherapy using IMRT with a simultaneous integrated boost SIB technique Vicente Bruzzaniti Armando Abate Massimo Pedrini Marcello Benassi and Lidia Strigari Abstract Background An advantage of the Intensity Modulated Radiotherapy IMRT technique is the feasibility to deliver different therapeutic dose levels to PTVs in a single treatment session using the Simultaneous Integrated Boost SIB technique. The paper aims to describe an automated tool to calculate the dose to be delivered with the SIB-IMRT technique in different anatomical regions that have the same Biological Equivalent Dose BED . IsoBED compared to the standard fractionation. Methods Based on the Linear Quadratic Model LQM we developed software that allows treatment schedules biologically equivalent to standard fractionations to be calculated. The main radiobiological parameters from literature are included in a database inside the software which can be updated according to the clinical experience of each Institute. In particular the BED to each target volume will be computed based on the alpha beta ratio total dose and the dose per fraction generally 2 Gy for a standard fractionation . Then after selecting the reference target . the PTV that controls the fractionation a new total dose and dose per fraction providing the same isoBED will be calculated for each target volume. Results The IsoBED Software developed allows 1 the calculation of new IsoBED treatment schedules derived from standard prescriptions and based on LQM 2 the conversion of the dose-volume histograms DVHs for each Target and OAR to a nominal standard dose at 2Gy per fraction in order to be shown together with the DV-constraints from literature based on the

TỪ KHÓA LIÊN QUAN
TÀI LIỆU MỚI ĐĂNG
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.