TAILIEUCHUNG - Recent Advances in Vibrations Analysis Part 7

Tham khảo tài liệu 'recent advances in vibrations analysis part 7', kỹ thuật - công nghệ, cơ khí - chế tạo máy phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | Probabilistic Vibration Models in the Diagnosis of Power Transformers 109 current and the vibration at the core is proportional to the square of the voltage. They also consider the temperature of the transformer as an important parameter in their model so they complemented their analytical model with complex variables that represent the real and imaginary part of the amplitude of the vibration the current and the voltage respectively at the main frequency component. Other parameters are the oil temperature and the geography of the transformer. These parameters must be defined through measurements taken off-line for each kind of transformer. Their diagnosis method consists of the estimation of the tank vibration and its comparison with the real measure. If the difference is greater that certain threshold then a fault is detected. The Russian experiments Golubev et al. 1999 install accelerometers in both sides of the transformer in order to acquire vibration measurements while the transformer is working properly. They executed two sets of experiments. In the first experiments no load is included in order to detect the vibration pattern due to the core. In the second set of experiments load is included for detecting vibration from both core and winding. Thus they subtract the effect of both minus the effect of the core to deduce the effects of the winding. With this information they calculate four coefficients that reflect the clamping pressures. If these coefficients exceed 90 then the clamping pressure is in a good state. Between 80 and 90 the pressure is in a fair state but the transformer can continue operating. Below 80 the pressure is critical and requires immediate attention. This approach has been tested in more than 200 transformers 110-500 kV to 50 MVA in Russia with a rate of more than 80 confirmed diagnosis. Also Manitoba Hydro power plants in Canada tested their large power transformers with this methodology with good results. The approaches commented .

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.