TAILIEUCHUNG - Power Quality Monitoring Analysis and Enhancement Part 15

Tham khảo tài liệu 'power quality monitoring analysis and enhancement part 15', kỹ thuật - công nghệ, cơ khí - chế tạo máy phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | Voltage Sag Mitigation by Network Reconfiguration 337 Determination of weak area Fault analysis simulations were done for all the buses of voltage level of 11kV and below except the main substations and the buses that are supplied through more than one feeder. The buses 1 2 3 17 18 33 34 35 36 39 40 41 42 and 43 are excluded from simulation where bus 1 is the main source buses 2 and 17 are the main substations buses 3 and 18 are supplied by two feeders bus 33 is a service bus for local loads and the buses 34 35 36 39 40 41 42 and 43 are at 33KV voltage level. The voltage sag distribution on all system buses Fig. 12. Voltage sag distribution on system buses due to three phase fault Fig. 13. Voltage magnitudes of system buses after steady state load flow and during three phase fault at bus 22 From Fig. 12 it is obvious from the dark points of voltage sag distribution Z-axis that buses 19 20 22 23 and 24 are the most sensitive in propagating voltage sags throughout the system. This group of buses is considered as weak area in the system. In the same manner 338 Power Quality - Monitoring Analysis and Enhancement bus 22 is considered as the weakest bus in this group and in the system. It is considered as the most sensitive bus in propagating voltage sags where most system buses are affected due to the fault event at this bus. The voltage distribution due to three phase fault at bus 22 is shown in Fig. 13 along with base case voltage profile of the system. From this figure it is clear that all bus voltage magnitudes are within standard limits during steady state but causes voltage sag at most buses due to a three phase fault at bus 22. Fig. 14 shows the voltage distribution with varying degree of darkness of phase A at all the system buses due to single line to ground fault at various fault locations. The same fault locations are again noted as the most sensitive buses in propagating sags throughout the whole system. Bus 22 is considered as the weakest bus in the .

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.