TAILIEUCHUNG - Power Quality Monitoring Analysis and Enhancement Part 10

Tham khảo tài liệu 'power quality monitoring analysis and enhancement part 10', kỹ thuật - công nghệ, cơ khí - chế tạo máy phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | 212 Power Quality - Monitoring Analysis and Enhancement indices accurately represent the transient characters of the transient disturbances. IRMS can accurately represent the RMS accommodating the time information. IHDR mainly represents the harmonic component relative to the pure sinusoid fundamental. However IWDR focuses on the fundamental component distortion of the transient disturbances and also the harmonic distortion. Therefore there is the similar result between IHDR and IWDR when the transient oscillation is analyzed that is very different from the results of low frequency disturbances. IAF represents the instantaneous average frequency of the transient disturbances and denotes the rated frequency when there is no disturbance occurred. PSCAD EMTDC simulated disturbances A simple distribution model is built in PSCAD EMTDC and two transient disturbances voltage sag and capacitor switching which are two most common disturbances are obtained to illustrate the performance of four power quality indices. a b Fig. 5. Voltage sag due to A phase grounded fault a Voltage sag waveform. b S-transform based time frequency distribution of voltage sag S-Transform Based Novel Indices for Power Quality Disturbances 213 A voltage sag caused by A phase grounded fault is simulated and the waveform of A phase voltage is shown in Fig. 5 a . Fig. 5 b shows the time frequency distribution based on S-transform. The disturbance occurs at and ends at . The four power quality indices RMS IHDR IWDR and IAF are calculated and a summary of these indices is show in Tab. 1. Similar to the results of the voltage sag in case1 the IRMS is and the IWDR is during the disturbance occurred. The steady values of IRMS and IWDR are and 0. There are also two peaks in the IHDR and IAF corresponding to the start and end time which are and 190Hz at and and 109Hz at respectively. Compared with the voltage sag in case1 this disturbance is not start .

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.