TAILIEUCHUNG - ARNOLD, K. (1999). Design of Gas-Handling Systems and Facilities (2nd ed.) Episode 2 Part 10

Tham khảo tài liệu 'arnold, k. (1999). design of gas-handling systems and facilities (2nd ed.) episode 2 part 10', kỹ thuật - công nghệ, cơ khí - chế tạo máy phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | Valves Fittings and Piping Details 461 text continued from page 453 insulation for personnel safety is required only when accidental contact of the hot surfaces could be made by personnel within normal work or walk areas. Isolation may be in the form of guards or barriers and in special cases warning signs. Hot surfaces associated with natural gas compressors and pumps handling volatile flammable fluids should be insulated since the equipment itself is a source of hydrocarbon liquids or gases. Generators electric motors and engine-driven equipment such as fire water pumps wireline units welding machines hydraulic equipment and the like do not themselves cause the area to become classified from an electrical standpoint. However they may be in a classified area due to other equipment and thus require insulation or barriers. Turbo-chargers exhaust manifolds compressor heads expansion bottles and the like including associated piping which cannot be insulated without causing mechanical failure are not normally insulated. In these cases warning signs barriers gas detectors or other methods for the protection of personnel and minimizing exposure to hydrocarbon liquids and gases are acceptable. MISCELLANEOUS PIPING DESIGN DETAILS Target Tees Where 90 turns in piping are required standard long radius ells ell centerline radius equals times pipe nominal diameter are usually used. In sandy service the sand has a tendency to erode the metal on the outside of the bend. Target tees such as shown in Figure 15-25 are often specified for such service. The sand builds up against the bull plug and provides a cushion of sand that is constantly being eroded and subject to deposition by the sand in the flow stream. Chokes The flow of fluid leaving a choke is in the form of a high-velocity jet. For this reason it is desirable to have a straight run of pipe of at least ten pipe diameters downstream of any choke prior to a change in direction so that the jet does not impinge on the .

TỪ KHÓA LIÊN QUAN
TÀI LIỆU MỚI ĐĂNG
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.