TAILIEUCHUNG - Process Engineering Equipment Handbook 2009 Part 11

Tham khảo tài liệu 'process engineering equipment handbook 2009 part 11', kỹ thuật - công nghệ, cơ khí - chế tạo máy phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | L-16 Life-Cycle Assessment FIG. L-8 Typical blade root-disc serration configuration. Source Liburdi Engineering. FIG. L-9 The cracks generally start inside on the bottom radius and are very difficult to detect in inspection. Source Liburdi Engineering. disastrous failures. This can be avoided and disc lives extended to 100 000 h by using performance-monitoring software to analyze changes to the disc cooling. Note that before this was done changing the disc material was tried but this did not work. The cracks persisted. The cracks were at the bottom of the fir tree and difficult to see. Note the following details from the figures Where cracks occurred Cracks along grain boundaries Root-disc gap configuration Compressor air and air hot-gas air paths are located at each disc root. Hot air accumulates where it shouldn t. Life-Cycle Assessment L-17 FIG. L-10 As found turbine disc cooling flows. Source Liburdi Engineering. TABLE L-3 Compare Measured and Predicted Values of Engine Parameters Source Liburdi Engineering Predicted Actual Increase combustor temperature Increase exhaust temperature Decrease compressor exit pressure lb in2 kPa Increase in fuel flow lb s kg s Solution Feed cool air through diaphragms. No rotating components affected just the diaphragms. Rows 3 and 4 had compressor delivery air row 5 had intermediate stage compressor air from bleed valve. Diagram of cooling air distribution See Table L-3. Net effect on performance negligible 70-hp 52-kW increase decrease in thermal efficiency 12 F 7 C increase in TIT 1 C 2 F increase in exhaust temperature in2 kPa decrease in combustor shell Example case history 5. Power augmentation for a gas turbine in cogeneration service using steam injection. Operation of this system works best when Steam is injected only when a certain power is reached. All excess steam is injected and then the control system is allowed to vary IGVs

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.