TAILIEUCHUNG - Endovascular Aneurysm Repair - part 7

EP có thể được trồng bất thường đáng kể, và do đó là bất khả thi để xác định đường kính đại diện. Thứ hai, thời gian khu vực xác định vận tốc dòng chảy của máu trong một xấp xỉ tuyến tính, và do khu vực (không phải là đường kính) Xác định huyết động IS đáng kể. | Does large oversizing of self-expandable endoprostheses compensate for aortic growth I 79 planted EP can be considerably irregular and therefore it is impossible to define the representative diameter. Second area times velocity defines the blood flow in a linear approximation and therefore the area not the diameter is determining the hemodynamic significance. This study 13 evaluates the performance of different types of oversized covered EPs in a normal juvenile porcine aorta by analyzing the lumen area over time and assesses the healing response of the underlying vessel. Material and methods I Endoprostheses Four different types of oversized self-expandable EPs were evaluated Fig. 1 . Manufacturers indicated a standard nominal diameter of 20 mm and a length varying between 40 to 60 mm when the EPs are fully expanded ex vivo. We calculated their nominal area to 314 mm2 using the formula area re X r2 Four EPs of each type were implanted. They were supplied sterile and by courtesy of the manufacturers WORLD MEDICAL manufacturing corp. Sunrise Florida USA Stenford Groupe Valendons . Nanterre France Schneider Europe AG Bulach Switzerland . The four types of EPs were Fig. 1. Four types of endoprostheses used in this study Talent TalentLoPro Stenway and Wallstent eft to right Reprinted with permission from the Society for Vascular Surgery and the Association for Vascular Surgery Journal of Vascular Surgery 2003 38 1368-1375 80 I Experimental studies I Talent -EPs made of three monofilament mm nitinol serpentines in series connected with a single monofilament. The outer covering was a fabric of woven low permeability polyester mm . The total length was 50 mm including the zigzag-shaped open web that had no fabric between the triangles. The EPs were mounted on a 20 F delivery catheter with a central balloon and were constrained by a retractable sheath. I Talent LoPro -EPs contained the same metallic frame as mentioned above yet the covering was made of .

TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.