TAILIEUCHUNG - Rules of Thumb for Mechanical Engineers 2010 Part 3

Tham khảo tài liệu 'rules of thumb for mechanical engineers 2010 part 3', kỹ thuật - công nghệ, cơ khí - chế tạo máy phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | 40 Rules of Thumb for Mechanical Engineers and for no change of phase flow of shell diameter. If there is no change of phase in the shell-side fluid the baffle pitch should not exceed the shell inside diameter. Otherwise the fluid would tend to flow parallel with the tubes rather than perpendicular to them resulting in a poorer heat transfer coefficient. Impingement baffles are required on shell-side inlet nozzles to protect the bundle against impingement by the incoming fluid when the fluid 1. is condensing 2. is a liquid vapor mixture 3. contains abrasive material 4. is entering at high velocity In addition TEMA requires bundle impingement protection when nozzle values of pu2 fluid density kg m3 times velocity squared m2 s2 exceed 1. 2 230 kg m-s2 for noncorrosive nonabrasive singlephase fluids 2. 744 kg m-s2 for all other liquids Also the minimum bundle entrance area should equal or exceed the inlet nozzle area and should not produce a value of pu2 greater than 5 950 kg m-s2 per TEMA. Impingement baffles can be either flat or curved. In order to maintain a maximum tube count the impingement plate is sometimes located in a conical nozzle opening or in a dome cap above the shell. The impingement plate material should be at least as good as that of the tubes. Sources 1. Standards of Tubular Manufacturers Association 7th Ed. TEMA Tarrytown NY 1988. 2. Cheremisinoff N. p. Heat Transfer Pocket Handbook. Houston Gulf Publishing Co. 1984. Shell Configurations The following notes summarize design features of shells for shell-and-tube heat exchangers. The single-pass shell is the most common shell construction used. The shell-side inlet and outlet nozzles are located at opposite ends of the shell. The nozzles can be placed on opposite or adjacent sides of the shell depending on the number and type of baffles used. A typical one-shell pass exchanger with horizontal segmental baffles is iUustrated in Figure 23 A TEMA E . A two-pass shell uses a longitudinal baffle to direct

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.