TAILIEUCHUNG - Báo cáo y học: "Effect of lung compliance and endotracheal tube leakage on measurement of tidal volume"

Tuyển tập các báo cáo nghiên cứu về y học được đăng trên tạp chí y học Critical Care cung cấp cho các bạn kiến thức về ngành y đề tài: Effect of lung compliance and endotracheal tube leakage on measurement of tidal volume. | Available online http content 8 6 R398 Research Effect of lung compliance and endotracheal tube leakage on measurement of tidal volume Sami I Al-Majed1 John E Thompson2 Kenneth F Watson3 and Adrienne G Randolph4 Open Access Attending in Pediatric pulmonary and Intensive Care and Director of Pediatric ICU Dhahran Health Center Saudi ARAMCO Saudi Arabia 2Director of Respiratory Care and Biomedical Engineering Children s Hospital Boston Boston MA USA 3Coordinator of Clinical Research Respiratory Care Department Children s Hospital Boston Boston MA USA 4Associate Professor of Anesthesia Pediatrics Harvard Medical School Boston MA USA Director of Patient Safety and Quality Improvement Medical-Surgical ICU Senior Associate in Critical Care Department of Anesthesia Children s Hospital Boston Boston MA USA Corresponding author Adrienne G Randolph Received 30 January 2004 Revisions requested 18 March 2004 Revisions received 11 August 2004 Accepted 15 August 2004 Published 6 October 2004 Critical Care 2004 8 R398-R402 DOI cc2954 This article is online at http content 8 6 R398 2004 Al-Majed et al. licensee BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License http licenses by which permits unrestricted use distribution and reproduction in any medium provided the original work is properly cited. Abstract Introduction The objective of this laboratory study was to measure the effect of decreased lung compliance and endotracheal tube ETT leakage on measured exhaled tidal volume at the airway and at the ventilator in a research study with a test lung. Methods The subjects were infant adult and pediatric test lungs. In the test lung model lung compliances were set to normal and to levels seen in acute respiratory distress syndrome. Set tidal volume was 6 ml kg across a range of simulated weights and ETT sizes. Data were

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.