TAILIEUCHUNG - The Intensive Care Manual - part 2

Huyết áp được đo bởi một ống thông trong động mạch phụ thuộc vào mức độ nào đó về tài sản của tàu cannulated. Các dạng sóng áp lực động mạch dễ bị đồ tạo tác, chẳng hạn như roi ống thông và giảm xóc, ảnh hưởng đến tính hợp lệ của dữ liệu áp lực | 2 Intravascular Access and Hemodynamic Monitoring 27 left ventricle and therefore implies contractility information and the rate of downstroke in the arterial waveform allows inferences regarding systemic vascular resistance. The blood pressure measured by an intra-arterial cannula depends to some extent on the properties of the vessel cannulated. The arterial pressure waveform is susceptible to artifacts such as catheter whip and damping which influence the validity of the pressure data. Catheter whip or systolic amplification occurs when arterial pressure waves are reflected back to the catheter tip from points of constriction branching or noncompliant arterial walls. Reflection of pressure waves off arterial walls can distort pressure waveforms causing overreading of systolic pressure. Peripheral catheters are more susceptible to systolic amplification because the velocity of blood flow increases gradually as the blood pulse moves peripherally since the walls of the large arteries are more compliant and absorb energy. The systolic pressure increases and the systolic wave narrows progressively as the arterial pressure wave is measured more peripherally and systolic amplification of the waveform increases as the compliance of the arteries decreases peripherally. Spontaneous oscillation is a characteristic of fluid-filled transducer systems. The resonant frequency of a transducer system is the inherent oscillation frequency produced by a pressure signal introduced into the system. Mechanical transducers absorb some of the energy of the systems they monitor and release of some of this energy. This causes a vibration to occur at the natural resonance frequency specific to the system. Damping is the tendency for the vibration or oscillation to stop and is a function of compliance air tube length tube coiling connections in the tubing and stopcocks. Air in the form of bubbles in the flush solution is very compressible and absorbs a great deal of energy resulting in .

TÀI LIỆU MỚI ĐĂNG
337    139    1    26-11-2024
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.