TAILIEUCHUNG - New Perspectives in Biosensors Technology and Applications Part 12

Tham khảo tài liệu 'new perspectives in biosensors technology and applications part 12', kỹ thuật - công nghệ, cơ khí - chế tạo máy phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | 322 New Perspectives in Biosensors Technology and Applications Fig. 15. Implementation of the pH-to-digital modulator The transfer function of the pH-to-digital converter can be derived as follows Y 1 C4 VH ----1 z ------E 12 C pH A 1 C2 J 1 C1 - 1 z-1 Ic J where Y denotes the average digital output of the quantizer and E indicates the quantization noise. When choosing C1 C2 the expression will be simplified to Y 2 VpH 1 - z-1 E 13 Furthermore the quantization noise is first-order shaped as expected. Through an on-chip simple digital filter realized by 14-bits up-down counter the digital average value of the comparator was obtained after shifting the bits of the output code depending on the sampled numbers. The high frequency quantization noise was filtered out. The general regenerative latch comparator shown in Fig. 12 was employed as the quantizer in the deltasigma modulator. The direct pH-to-digital converter derived is used to measure the pH response. The chip has been encapsulated in a standard dual inline package. The sensing art has been exposed to test solutions in the ion concentration range between pH 2 and 12. The measurements were performed under a power supply and the sampling frequency of the converter was MHz. Through an on-chip simple digital filter realized by 14-bits up-down counter the digital average value of the comparator was obtained after shifting the bits of the output code depending on the sampled numbers. Layout microphotograph of the pH-to-digital converter circuit is shown in Fig. 16. The circuit without pad occupied an area of X . The input range of the delta-sigma modulator is since the positive and negative reference voltages of the delta-sigma modulator are and respectively. The sensitivity of the pH-to-digital converter is 197 digital counts pH. The plot of the digital output versus pH value is shown in Fig. 17. Deviation between measured points and the linear regression line of sensitivity .

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.