TAILIEUCHUNG - Thiết kế đề phòng hỏa hoạn và lối thoát

Tham khảo tài liệu 'thiết kế đề phòng hỏa hoạn và lối thoát', kỹ thuật - công nghệ, kiến trúc - xây dựng phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | Building regulations require that due consideration must be given in buildings to - the flammability of building materials - the duration of fire resistance of the components expressed in terms of fire resistance classifications - the integrity of the sealing of openings - the arrangement of escape routes. The aim is to prevent the start and spread of a fire stem the spread of smoke and facilitate the escape or rescue of persons and animals. In addition consideration must be given to effective extinguishing of a fire. Active and passive precautions must be taken to satisfy these requirements. Active precautions are those systems that are automatically deployed in the event of fire passive precautions are the construction solutions in the building and its components. Active precautions include smoke and fire alarm systems sprinkler systems water spray extinguisher plant co2 extinguishing installations powder and foam extinguisher plant and automatic smoke and heat venting systems. Passive precautions relate mainly to minimum structural sections casings and coatings. In addition to these other important measures are the layout of rising mains installation of fire doors and fire windows construction of supporting floors water cooling of hollow steel profiles and the dimensioning of casings and coatings for steel profiles. Fire detectors A fire detector is a part of the fire alarm system and can trigger a transmitting device that raises the alarm in a remote control centre. There are automatic and nonautomatic fire detectors. The latter are those which can be activated manually. Automatic fire detectors are parts of the overall fire alarm system that sense changes in specific physical and or chemical parameters either continuously or sequentially in set time intervals to detect a fire within the monitored area. They must be - installed in sufficient numbers and be suited to the general arrangement of the area to be monitored - selected according to the fire risk - .

TÀI LIỆU LIÊN QUAN
TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.