TAILIEUCHUNG - Báo cáo hóa học: "Research Article Design of a Versatile and Low Cost μVolt Level A to D Conversion System for Use in Medical Instrumentation Applicatio"

Tuyển tập báo cáo các nghiên cứu khoa học quốc tế ngành hóa học dành cho các bạn yêu hóa học tham khảo đề tài: Research Article Design of a Versatile and Low Cost μVolt Level A to D Conversion System for Use in Medical Instrumentation Applicatio | Hindawi Publishing Corporation EURASIP Journal on Advances in Signal Processing Volume 2008 Article ID 370171 6 pages doi 2008 370171 Research Article Design of a Versatile and Low Cost Volt Level A to D Conversion System for Use in Medical Instrumentation Applications Kerry Williamsand Neil Robinson School of Applied Sciences RMIT University Melbourne Victoria 3000 Australia Correspondence should be addressed to Kerry Williams Received 27 November 2007 Revised 3 April 2008 Accepted 14 August 2008 Recommended by . Chung Modern medical facilities place considerable reliance on electronic instrumentation for purposes of calibration and monitoring of therapeutic processes many of which employ electrical and electronic apparatus that itself generates considerable levels of interference in the form of background electromagnetic radiation EMR . Additionally diverse ambient conditions in the clinical environment such as uncontrolled temperature humidity noise and vibration place added stress on sensitive instrumentation. In order to obtain accurate repeatable and reliable data in such environments instrumentation used must be largely immune to these factors. Analogue instrumentation is particularly susceptible to unstable environmental conditions. Sensors typically output an analogue current or voltage and it can be demonstrated that considerable overall benefit to the measuring process would result if sensor outputs could be converted to a robust digital format at the earliest possible stage. A practical and low cost system for A to D conversion at Volt signal levels is described in this work. It has been successfully employed in portable radiation dosimetry instrumentation and used under diverse clinical conditions and it affords an improvement in signal resolution in excess of an order of magnitude over commonly used analogue techniques. Copyright 2008 K. Williams and N. Robinson. This is an open access article distributed under .

TÀI LIỆU LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.