TAILIEUCHUNG - Plastics Technology Handbook 2011 Part 8

Tham khảo tài liệu 'plastics technology handbook 2011 part 8', kỹ thuật - công nghệ, cơ khí - chế tạo máy phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | 3-44 Plastics Technology Handbook motor FIGURE Scheme of a Weissenberg Rheogoniometer. which is measured by means of a transducer. The polymer sample is placed in the space between the cone and plate and the torque experienced by the stationary cone is measured for different rotational speeds of the plate. Relating the shear stress at the cone surface to the measured torque and the shear rate to the angular velocity of the plate the expression for the viscosity h is obtained as 3KỠ sin a h Z 2pRpu where K is the torsional constant and q is the deflection of the spring Rp is the radius and u is the angular velocity of the plate and a is the angle of the cone. While q and u are experimentally determined quantities K and a are obtained by calibration on other materials. The cone and plate viscometer gives reliable experimental data over an extensive range of shear rates 10 4 104 sec-1 . Not only can it be used to measure viscosities in simple shear but it can also be used to determine the dynamic properties of viscoelastic materials. The unit is also set up to measure the normal stresses exhibited by viscoelastics . those perpendicular to the plane of shear. Capillary Rheometers These rheometers are widely used to study the rheological behavior of molten polymers. As shown in Figure the fluid is forced from a reservoir into and through a fine-bore tube or capillary by either mechanical or pneumatic means. The fluid is maintained at isothermal conditions by electrical temperature control methods. Either the extrusion pressure or volumetric flow rate can be controlled as the independent variable with the other being the measured dependent variable. Under steady flow and isothermal conditions for an incompressible fluid assuming only axial flow and no slip at the wall the viscous force resisting the motion of a column offluid in the capillary is equal to the applied force tending to move the column in the direction of flow. Thus RAP 2L .

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.