TAILIEUCHUNG - HANDBOOK OF CARDIAC PACING – PART 8

Căng thẳng bổ sung có thể được cased nén dẫn từ xương sườn và xương đòn khi điện cực được cấy ghép ở một vị trí trung gian liên quan đến xương sườn đầu tiên. Cuối cùng, hình 11,13 cho thấy PA xuất hiện bình thường và ngực bên x-ray. Trong ví dụ này, các điện cực được đặt vào tâm nhĩ và tâm thất với số lượng thích hợp của slack trong buồng mỗi. | 104 Handbook of Cardiac Pacing leads as they pass through the soft tissue structures ligament and muscle before entering the subclavian vein. Additional stress may be cased by compression of the leads from the first rib and the clavicle when the leads are implanted in a medial postion relative to the first rib. Finally Figure shows a normal appearing PA and lateral chest x-ray. In this example the leads are properly placed into the atrium and ventricle with appropriate amounts of slack in each chamber. Fig. . Normal appearing lead placement Radiograph. a. PA radiograph taken with the patient upright with a full inspiration. This is a dual chamber pacemaker with normal appearing lead placement. The atrial lead is in the right atrial appendage and the ventricular lead in the right ventricular apex. The leads have adequate slack and there are no defects or kinks noted. 11 Fig. . Lateral radiograph of the same patient. Note the anterior position of both leads. NBD Code for Implantable Cardioverter Defibrillators The implantable cardioverter defibrillator ICD has revolutionized the treatment of lethal tachyarrhythmias. New devices are being designed for the treatment of atrial fibrillation as well. As these devices are quite a bit different in function and have different features than their pacemaker cousins they need their own descriptive codes. As described in chapter 1 the North American Society of Pacing and Electrophysiology and the British Pacing and Electophysiology Group NASPE and BPEG or the NBG developed a system known as the NBG Code to describe the functionality of pacemakers. The fifth position of the code is meant to describe the antitachycardia features of a device. In 1993 the NBG developed another code that was directed at devices whose primary function was that of treating tachycardia rather than bradycardia. This code is very similar to the NBG Code and is known as the NBD Code NASPE-BPEG Defibrillator Code . The positions of the NBD

TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.