TAILIEUCHUNG - FIBRO Gas Springs The Safer Choice

FIBRO Gas Springs – The Safer Choice At FIBRO, safety has always been a top priority. Below is what we do to help you provide a safer working environment. FIBRO Safety Features Excessive Return Speed Protection System Designed for controlled gas venting through piston rods with integral safety stops and specially designed guides. | FIBRO Gas Springs The Safer Choice . FIBRO GmbH Division Standard Parts Postfach 1120- DE-74851 Hassmersheim Tel. 49 0 62 66-73-0 Fax 49 0 62 66-73-139 info@ FIBRO Gas Springs - The Safer Choice At FIBRO safety has always been a top priority. Below is what we do to help you provide a safer working environment. FIBRO Safety Features Advice to Gas Spring Buyers Excessive Return Speed Protection System Designed for controlled gas venting through piston rods with integral safety stops and specially designed guides. Excessive Return Speed Safety should have always be a top priority. Therefore we believe gas springs for metal forming tools should unless the maximum allowable pressure PS is less than or equal to bar be ordered with the following safety requirements 1 Piston rods with an integral safety stop. 2 Designed produced and tested according to Pressure Equipment Directive PED 97 23 EC for a minimum of 2 000 000 full cycles at highest allowed charging pressure at highest allowed running temperature for all specified mounting methods including top mount Type C Flange Mounts according to ISO 11901-2 Please Note Unless the maximum pressure is less than or equal to bar all gas springs produced sold installed and or used within the EU should be designed produced and tested in accordance wth PED 97 23 EC. Over-Pressure Protection System Over-Pressure Condition Pressure Vessel Approval FIBRO OverPressure Protection System is designed to vent excessive gas pressure in a controlled manner. FIBRO Gas Springs arre designed produced and tested according to PED 97 23 EC for 2 000 000 full cycles at the highest allowed chraging pressure the highest allowed running temperature and for all specified mounting methods. unless other value stated on the springs Over-Stroke Protection System Over-Stroke FIBRO has a developed unique System. The cylinder wall is designed to deform in a predefined way venting the internal gas .

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.