TAILIEUCHUNG - Introdution to Thermal Analysis Techniques and Applications Part 8

Tham khảo tài liệu 'introdution to thermal analysis techniques and applications part 8', kỹ thuật - công nghệ, cơ khí - chế tạo máy phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | This page intentionally left blank EVOLVED GAS ANALYSIS EGAI Basic Principles Many samples. on heating release gases or vapour through desorption or decomposition. Illis release IS accompanied by thermal effects and. obviously mass-losses which themselves can be detected by the appropriate thermal analysts technique . DTA or DSC and TG. respectively. The thermal analysis technique docs not. however identify the gas evoked and. for complex decompositions such information is essential. It has thus become fairly routine to couple the basic techniques already described w ith a system for either detecting the evolution of gas or gases from the sample evolved gas detection. EGD or. more satisfactorily. detecting and identifying the gases evolved moAcd gas anahits. EGA I4 . The apparatus for EGA will obviously be more complex than that required for EGD. Gas-solid reactions can also he studied by determining die amounts of products formed or reactant gits consumed. A novel technique on this principle is pulsed gad thermal analysis 5 we below . In practice the main techniques in current use for EGA arc mass spectrometry MS or Fourier transform infrared spectroscopy l-TIR . Because of the time intervals required between sampling gas chromatography GC see below has declined in usage. If the evolved gas mixtures are SO complex that preliminary separation is required. GC may be used for the separation coupled with MS or FTIR for lie analysis. The main thermal analysis technique with which EGA has been coupled is thermogravimclry TG and simultaneous techniques see Chapter 7 arc usually indicated by hyphenation for example TG-MS or TG-FTIR. The practical aspects of coupling EGA methods w ilh TA instruments have been discussed in considerable detail by Kaiserberger and Poo 6Ị The gas flow conditions in the combined instruments have to be carefully examined and correlation of the WO sets of data obtained from the twxi techniques by suitable calibration IS important. The .

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.