TAILIEUCHUNG - Oscilloscopes Episode 4

Tham khảo tài liệu 'oscilloscopes episode 4', kỹ thuật - công nghệ, cơ khí - chế tạo máy phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | 48 Oscilloscopes it impossible to remove the latter when it is desired to use a different graticule. The purpose of the tinted sheet is to improve the contrast between the trace and the rest of the screen. The brightness of the trace is reduced somewhat by the tinted sheet but the trace s light only has to pass through the sheet once. Ambient light on the other hand is attenuated as it passes through the sheet before being reflected from the . screen and attenuated again as it passes out resulting in improved contrast. The improvement is even greater for colours different from that of the trace. Increasingly a neutral grey-tinted sheet is used in place of one the same colour as the trace. The material is a special plastic sheet with the property of circularly polarizing light which passes through it. The trace is little attenuated because it is initially unpolarized and only passes through the filter once but ambient Figure The VC-7502 dual channel I00Ms s digital storage oscilloscope provides a 1 50 MHz bandwidth. GPIB and RS2Ỉ2 are standard and IEEE-defined pulse parameter measurements can be automatically measured. The VC-7504 is similar but has lour channels reproduced by courtesy of Hitachi Denshi UK Ltd Accessories 49 light falling on the screen of the . is circularly polarized. Upon reflection its circular polarization is now of the wrong hand to pass back through the filter resulting in much improved contrast. In particularly bright surroundings a mesh filter can be used. This is a fine metal mesh finished in matt black it reduces the brightness of the trace by about a quarter but provides very high attenuation of ambient light reflections. Special graticules have been developed for fitting to an oscilloscope in place of the standard one. A typical example is a graticule with nominal and limit markings for a sine-squared pulse-and-bar test waveform used for testing television equipment response times and differential gain and phase. Smith .

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.