TAILIEUCHUNG - Gas Turbines Part 14

Tham khảo tài liệu 'gas turbines part 14', kỹ thuật - công nghệ, cơ khí - chế tạo máy phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | 314 Gas Turbines Step 4. Calculate the possible maximal number of redundant graphs given by Max c - x Step 5. Initialize the number of initial node n 1 in the search and the number of assigned redundant graph ngR 0. Step 6. Calculate the possible distinct combinations of the initial nodes for each target selecting Vi nodes out of nk - 1 with nk the cardinality of set K this means Ị n c 1 k -------n for each target node I ni J nk -1 -ni ni Step 7. Assign the orientations of the Ị graphs using the set C nv for each target node including the cycle graphs no diagonal submatrix and constraints of the class d. Step 8. Bring up the number nSR according the assigned redundant graphs if nSR Max. end the algorithm otherwise continue. Step 9. If ni nk - 1 end the algorithm on the contrary Hi Hi 1 an return to step 6. 3. Gas turbine description The GT behavior model used at this work simulates electrical power generation in a combined cycle power plant configuration with two GT two heat recovery-steam generators and a steam turbine. At ISO conditions the ideal power delivered for each GT generates 80MV and the steam turbine 100 MV This model may go from cold startup to base load generation. The main components of the GT shown in Fig. 3 are compressor C combustion chamber CC gas turbine section T electric generator EG and heat recovery HRSG. Fig. 3. Components of the Gas Turbine Application of Structural Analysis to Improve Fault Diagnosis in a Gas Turbine 315 Fig. 4. Gas Turbine Variables Interconnection The GT unit has two gas fuel control valves the first supplies gas fuel to CC and the second one supplies gas fuel to heat-recovery afterburners starting a second- additional combustion at heat recovery for increasing the exhaust gases temperature . A generic compressor bleed valve extracts air from compressor during GT acceleration avoiding an stall or surge phenomena. Also the GT unit has an actuator for the compressor inlet guide vanes IGVs to get the required air flow to .

TỪ KHÓA LIÊN QUAN
TÀI LIỆU MỚI ĐĂNG
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.