TAILIEUCHUNG - báo cáo hóa học:" A comparison of two headless compression screws for operative treatment of scaphoid fractures"

Tuyển tập các báo cáo nghiên cứu về hóa học được đăng trên tạp chí sinh học quốc tế đề tài : A comparison of two headless compression screws for operative treatment of scaphoid fractures | Grewal et al. Journal of Orthopaedic Surgery and Research 2011 6 27 http content 6 1 27 JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH RESEARCH ARTICLE Open Access A comparison of two headless compression screws for operative treatment of scaphoid fractures Ruby Grewal Joseph Assini David Sauder Louis Ferreira Jim Johnson and Kenneth Faber Abstract Purpose The purpose of this study was to compare the interfragmentary compression force across a simulated scaphoid fracture by two commonly used compression screw systems the Acutrak 2 Standard and the mm Synthes headless compression screw. Methods Sixteen 8 pairs 6 female 2 male cadaver scaphoids were randomly assigned to receive either the Acutrak 2 or Synthes screw with the contralateral scaphoid designated to receive the opposite. Guide wires were inserted under fluoroscopic control. Following transverse osteotomy the distal and proximal fragments were placed on either side of a custom load cell to measure interfragmentary compression. Screws were placed under fluoroscopic control using the manufacturer s recommended surgical technique. Compressive forces were measured during screw insertion. Recording continued for an additional 60s in order to measure any loss of compression after installation was complete. The peak and final interfragmentary compression were recorded and paired t-tests performed. Results The mean peak compression generated by the Acutrak 2 Standard was greater than that produced by the Synthes compression screw N vs. N respectively p . The mean final interfragmentary compression generated by the Acutrak 2 screw N was significantly greater p than the Synthes screw N . Specimens typically reached a steady state of compression by 120-150s after final tightening. Conclusion Peak interfragmentary compression observed during screw installation was similar for both screw systems. However the mean interfragmentary compression .

TÀI LIỆU LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.