TAILIEUCHUNG - Thermal Analysis - Fundamentals and Applications to Polymer Science Part 3

Tham khảo tài liệu 'thermal analysis - fundamentals and applications to polymer science part 3', kỹ thuật - công nghệ, cơ khí - chế tạo máy phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | Page 22 sample preparation and the experimental conditions to improve the data rather than correct the data by computer. Automated TA Systems When large numbers of samples are routinely measured for example in quality control an automated sample supplier can be fitted to the TA unit. Samples are handled and placed in the instrument by a robot arm and removed after measurements have been completed. At present robot arms are commercially available for DSC TG-DTA and TMA instruments. An automated sample supplier is shown in Figure . Simultaneous TA Various TA apparatus can be combined so that several physical properties can be measured simultaneously. Table lists the most commonly available simultaneous analysis instruments. Simultaneous TA can be useful in unequivocally assigning thermal events. However experimental conditions may be compromised. For example in a TG-DTA experiment the microbalance may not attain its maximum resolution while heating at 20 K min in a helium atmosphere purging at 50 ml min. Installation and Maintenance The following points should be considered when installing a DSC or DTA instrument in a laboratory. 1 The apparatus should be placed on a level surface approximately 1 m above floor level. 2 The ambient temperature in the vicinity of the instrument should be maintained as constant as possible between 288 and 303 K with a relative humidity 75 . Where the relative humidity exceeds 75 the instrument should be located in an air-conditioned room. 3 The electric power supply must be stable and a voltage regulator should be used to isolate the apparatus from voltage fluctuations. In the event of a power failure the instrument will shut down but the switches on the instrument remain in the on position. When the power is restored the instrument modules will power-up in a random sequence and the probability of damaging the instrument is high. The electric supply should be latched so that when the electric supply is restored the

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.