TAILIEUCHUNG - GENERAL ELECTRIC GENERATING PLANTS Part 6

Tham khảo tài liệu 'general electric generating plants part 6', kỹ thuật - công nghệ, cơ khí - chế tạo máy phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | MIL-HDBK-1003 11 fuel oil centrifuging of all fuels delivered by water transport as fuels can be easily contaminated with water or solids. Provide heating for heavy fuel oils and in cold climates for all fuels. Filtration shall be provided for all types of fuel. Comply with applicable state and local regulations concerning storage and treatment of fuels. Conversion Fuel. On prime duty Design 2 plants provide additional space for installing future additions to the fuel handling equipment for example fuel storage for residual fuel and pilot diesel fuel if required plus residual fuel heaters and centrifuges dirty fuel tanks and similar items. Fuel Storage and Day Tank Volumes. Use above-ground storage tanks within diked areas. Provide 30-day storage capacity for prime duty plants and 7-day storage for standby emergency duty plants unless local conditions will allow less or require greater volume. Storage tank volume shall be based on the rate of fuel consumption of all engines including spares at 100 percent load multiplied by a operating factor. Tanks should be selected in standard manufactured sizes and should be vertical or horizontal as best suits the site conditions. The use of underground storage tanks may be considered for small plants if leak detection and double containment provisions are provided. Day tank volumes shall be determined based on the following Prime Duty Plants. Provide a day tank for each engine with storage for not less than 2 hours full load operation and with automatic transfer pumps and level controls. Standby Emergency Duty Plants in Standby Service. Provide manually-filled day tanks each of a capacity able to satisfy 8 hours of full load operations. Standby Emergency Duty Plants in Emergency Service. Provide a day tank and transfer pump unit for each engine as recommended by the engine manufacturer. Interior tank capacities shall not exceed the requirements given in the National Fire Protection .

TÀI LIỆU MỚI ĐĂNG
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.