TAILIEUCHUNG - Power Quality Monitoring Analysis and Enhancement Part 2

Tham khảo tài liệu 'power quality monitoring analysis and enhancement part 2', kỹ thuật - công nghệ, cơ khí - chế tạo máy phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | Power Quality Monitoring 13 v ỉ l Z diagZ 1 24 where 1 is a matrix full of ones and such that its dimension is equal to the dimension of z. The square H X matrix Vdfv contains the sags at each bus of the network due to faults at each one of the buses. The during fault voltage at a general bus i when a fault occurs at that bus is contained in the diagonal of Vdfv and is zero for a solid three phase fault. Off-diagonal elements of Vdfv are the sags at a general bus k due to a fault at a general position Hence column contains the during-fault voltages at buses 1 2 . . H during the fault at bus This means that the effect in terms of sags of a fault at a given bus of the system is contained in columns of the voltage sag matrix. This information is usually presented on the single line diagram of the power system and it is called affected area. A sample II H sag matrix is shown as follows 0 1 12 1 it 22 1 21 0 1 hĩL. 11 1 Si 1 2 0 11 22 25 In tills chapter a real sample network is used for description of the voltage sag matrix. Fig. 3 shows a 41-bus 230-kV of Tehran Regional Electric Company in Iran. Fig. 3. Single line diagram of a 230 kv real case study 14 Power Quality - Monitoring Analysis and Enhancement Applying Equation 23 it is found the during fault voltages for the 41 buses due to the faults on each one of the 41 buses. Equation 26 shows the resulting voltage sag matrix. It is seen that column 34 of the sag matrix contains the during fault voltages at each one of the 41 buses when a three-phase fault occurs at bus 34. Column 34 of the sag matrix contains the information to draw the affected area of the system due to a fault at bus 34. 0 2 A 2 2 A 34 2 A 41 A 2 Z34 34 Al 41 1 A l Q 1 A 34 2 A 41 Zl l z34 34 Al 41 1 Z34 2 z34 41 Al 41 26 2 Al l 2 Al 2 2 Al 34 Q A 1 Z2 2 Z34 34 Fig. 4. Affected areas for three-phase fault at buses 34 and 21 The affected area contains the load buses that present a during fault voltage lower than a given value due to a fault at a .

TỪ KHÓA LIÊN QUAN
TÀI LIỆU MỚI ĐĂNG
8    171    3    11-01-2025
5    185    1    11-01-2025
26    147    2    11-01-2025
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.