TAILIEUCHUNG - Power Quality Harmonics Analysis and Real Measurements Data Part 12

Tham khảo tài liệu 'power quality harmonics analysis and real measurements data part 12', kỹ thuật - công nghệ, cơ khí - chế tạo máy phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | Part 4 Industrial Environments 9 Harmonics Effect in Industrial and University Environments . Shwehdi King Faisal University College of Engineering Al Ahsa Saudi Arabia 1. Introduction Analyzing harmonic distortion produced from lead blast furnace LBF A major cost to a steel factory facility is the energy used to power the arc furnace for the melting and refining process. Operation at low power factor results in additional voltage drop through the power system yielding a lower system voltage on the plant buses. Low system voltage increases the melt time and will add to the overall plant operating costs per ton. Low power factor can also result in additional costs in the form of penalties from the electric-utility company 1-2 8 . Capacitor can be applied in steel factory facilities for a wide range of benefits. The capacitors will improve the power factor of the system reduce billing penalties imposed by the electric power utility and increase system voltage-boosting productivity. The system losses are also reduced improving the electrical system efficiency. However harmonic sources in the steel mill can interact with capacitor banks resulting in problems if they are not properly applied. The effect of harmonics varies depending on the type of load. In some cases such as a resistance heating load all of the applied voltage does useful work although in most cases involving transformers and motors only the 60-Hz component of the voltage does useful work and the harmonic component generates useless heat. Sensitive electronic control circuits timers and logic circuits may be affected if the supply voltage is distorted 3-5 . The harmonic current generated by any non-linear load flows from the load into the power system. This current seeking a low impedance path to ground causes a voltage of the drop through the system according to Ohm s Law. The harmonic voltage combines with the 60 Hz voltages producing a distorted power system voltage. The harmonic laden power .

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.