TAILIEUCHUNG - Power Quality Harmonics Analysis and Real Measurements Data Part 6

Tham khảo tài liệu 'power quality harmonics analysis and real measurements data part 6', kỹ thuật - công nghệ, cơ khí - chế tạo máy phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | 3 Voltage Harmonics Measuring Issues in Medium Voltage Systems Jaroslaw Luszcz Gdansk University of Technology Poland 1. Introduction Voltage harmonic distortion level is one of the significant parameters of power quality in power system. Numerous problems related to voltage and current harmonic effects for contemporary power systems are commonly observed nowadays. Levels and spectral content of voltage distortions injected into electric power grids are tending to increase despite the fact that the acceptable levels are determined by numerous regulations. Voltage distortion assessments especially in middle and high voltage grids are usually based on measurements in which voltage transformers are commonly used. The transfer ratio of a voltage transformer fed by distorted primary voltage with harmonic components of frequency higher than fundamental can be different for high frequency components in comparison with the fundamental frequency. During the last decades primary problems related to voltage distortions have been usually encountered in frequency range up to 40th harmonic mostly in LV grids. Nowadays due to the evident increase of the overall power of nonlinear power electronic loads connected to grid and higher modulation frequencies widely used distorted voltage propagates deeply into MV grids and goes evidently beyond frequency of 2 kHz. This chapter presents problems of voltage harmonic transfer accuracy through voltage transformers which are usually used for power quality monitoring in medium and high voltage grids Kadar at al. 1997 Seljeseth at al. 1998 Shibuya at al. 2002 Mahesh at al. 2004 Yao Xiao at al. 2004 Klatt at al. 2010 . A simplified lumped parameters circuit model of the voltage transformer is proposed and verified by simulation and experimental investigations. A number voltage transformers typically used in medium voltage grid have been tested in the conducted disturbances frequency range up to 30 MHz. The obtained results prove that .

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.