TAILIEUCHUNG - ARNOLD, K. (1999). Design of Gas-Handling Systems and Facilities (2nd ed.) Episode 2 Part 13

Tham khảo tài liệu 'arnold, k. (1999). design of gas-handling systems and facilities (2nd ed.) episode 2 part 13', kỹ thuật - công nghệ, cơ khí - chế tạo máy phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | 536 Design of Gas-Handling Systems and Facilities ĩf đ Figure 17-24. Standard explosion-proof junction boxes and conduit fittings Courtesy of Crouse-Hinds Electrical Construction Materials a division of Cooper Industries Inc. 1. Confine internal explosions to explosion-proof enclosures and conduit systems. 2. Minimize the passage of gases and prevent the passage of flame through conduit or cable. 3. Prevent process gas or liquid in process piping from entering conduit or cable systems. 4. Prevent pressure piling. Pressure piling is a phenomenon caused by the fact that ignition in an enclosure can first pre-compress gases in a conduit or other enclosure to Electrical Systems 537 ELBOW SEAL DRAIN SEAL FOR SEALING IN VERTICAL OR HORIZONTAL CONDUIT RUNS FOR CONDUITS RUNNING AT ANY ANGLE BETWEEN VERTICAL AND HORIZONTAL Figure 17-25. Standard sealing fittings. Courtesy of Crouse-Hinds Electrical Construction Materials a division of Cooper Industries Inc. Through feed hubs CHICO A sealing compound Rib Holds seal securely Integral bushtng CHICO fiber Jam Cover may be removed for inspecting seal Barrier prevents seal from contacting cover Movement of this handle removes accumulated dirt Barriers lor sealing compound easily installed after dams are made and Delore compound IS poured Body may be installed with either conduil hub up Expiosionprool automatic drain prevents accumulation ol waler above the seal Maae of stainless Steel. Its flame fignt joint permits continuous drainage Figure 17-26. Cutaway drawing of a properly installed sealing fitting. Courtesy of Crouse-Hinds Electrical Construction Materials a division of Cooper Industries Inc. 538 Design of Gas-Handling Systems and Facilities which it is connected. When pre-compressed gases are then ignited in the second enclosure pressures exceeding those for which it has been tested can be reached. Receptacles and Attachment Plugs Receptacles and attachment plugs for Class I Division 1 and 2 areas must be approved for .

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.