TAILIEUCHUNG - Refrigeration and Air Conditioning 3E Episode 6

Tham khảo tài liệu 'refrigeration and air conditioning 3e episode 6', kỹ thuật - công nghệ, cơ khí - chế tạo máy phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | 12 Liquid chillers. Ice. Brines. Thermal storage Distributed cooling A building or process having a large number of separated cooling loads could have a refrigeration system for each of these loads. It will usually be more convenient to concentrate the cooling into one plant. The cooling effect of a central refrigerating system can be distributed by a heat-transferring liquid or secondary refrigerant. Where the working temperatures are always above 0 C such as in air-conditioning water is commonly used. At temperatures below this non-freezing liquids are used. Liquid chillers The preferred secondary refrigerant will be water if this can possibly satisfy the temperature requirement . if the load temperature is sufficiently above 0 C that water can be circulated without risk of freezing. The greatest demand for chilled water is in air-conditioning systems see also Chapters 23-28 . For this duty water is required at a temperature usually not lower than 5 C and for this purpose the evaporator will be of the shell-and-tube type operating with refrigerant temperatures close to freezing point. A very wide range of factory-built package chillers is available and models are mainly one-piece units with integral water-cooled condensers as shown in Figures and . Other types may have air-cooled or evaporative condensers and so require refrigerant pipe connections on site to these condensers. Sizes range from 14 kW to 35 000 kW most installations being within the range 100-1500 kW. At water temperatures close to freezing and with evaporators Liquid chillers. Ice. Brines. Thermal storage 145 which are vulnerable to ice damage it is important to have adequate safety controls to check the calibration of these frequently and to avoid interference by unauthorized persons. Nearly all troubles from packaged water chillers arise from a failure of safety controls. Several types of controls are in use frequently three or more on the same equipment but there should .

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.