TAILIEUCHUNG - Fiber Optic Cable Ruggedized Breakout Cables

ADC’s ruggedized breakout cables provide factory standard guaranteed performance specifications. They are 100% optically tested and are offered with a variety of optical performance levels. Features: • 245/900 or 500/900 μm polyester buffer • Flame retardant polyurethane jacket • Extremely rugged • Superior abrasion resistance • Excellent performance at extreme temperature • Compatible with all industry standard connectors | Fiber Optic Cable Ruggedized Breakout Cables SPEC SHEET ADC s ruggedized breakout cables provide factory standard guaranteed performance specifications. They are 100 optically tested and are offered with a variety of optical performance levels. Features 245 900 or 500 900 pm polyester buffer Flame retardant polyurethane jacket Extremely rugged Superior abrasion resistance Excellent performance at extreme temperature Compatible with all industry standard connectors Applications Military and tactical applications where cables are abused Outdoor use where quick retrieval and rough handling are necessary Electronic News Gathering environments ENG Security applications 1 - 9 5 2 - 9 3 8 - 8 0 8 0 1 - 8 0 0 - 3 6 6 - 3 8 9 1 Fiber Optic Cable Ruggedized Simplex and Duplex Cables Specifications Ruggedized Breakout Cables 6 Fiber Cable Flame Retardant Polyurethane Outer Jacket mm Flame Retardant Polyurethane Subunit Dielectric Central Strength Member Aramid Yarn Strength Member 900 pm Polyester Tight Buffer 245 or 500 pm Acrylate Coated Fiber Environmental Characteristics Storage Temperature -55 to 85 C -67 to 185 F Operating Temperature -40 to 85 C -40 to 185 F Installation Temperature -40 to 85 C -40 to 185 F Mechanical Characteristics Test Procedure Units Results Crush Resistance EIA-FOTP-41A N cm 1200 Impact Resistance EIA-FOTP-25B of impacts 500 Flexing of Cycles EIA-FOTP-104A of cycles 10 000 Maximum Pulling Load EIA-FOTP-33A N lb 2000 1 12 Maximum Operating Load EIA-FOTP-33A N lb 1000 67 Min. Bend Radius @ Max Load EIA-FOTP-33A 15 x Cable OD Low Temperature Bend Test EIA-FOTP-37A C F Passed @ -40 -40 1-952-938-8080 1-800-366-3891 Fiber Optic Cable Ruggedized Breakout Cables Construction Characteristics Ruggedized Breakout Cables Strand Count Single Jacket mm in Dual Jacket mm in 4 fiber 6 fiber 8 fiber 12 fiber 18 fiber 24 fiber .

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.