TAILIEUCHUNG - Effects of temperature and solution composition on evaporation of iodine as a part of estimating volatility of iodine under gamma irradiation

The evaporation of I2 was observed to follow primarily first order kinetics, depending on the I2 concentration. The evaporation rate constant increased rapidly with increase in temperature. The presence of Ie slightly reduced the evaporation rate of I2 by forming relatively stable I 3 . The effect of Cle at | Effects of temperature and solution composition on evaporation of iodine as a part of estimating volatility of iodine under gamma irradiation Nuclear Engineering and Technology 49 (2017) 1689e1695 Contents lists available at ScienceDirect Nuclear Engineering and Technology journal homepage: Original Article Effects of temperature and solution composition on evaporation of iodine as a part of estimating volatility of iodine under gamma irradiation Jei-Won Yeon*, Sang-Hyuk Jung Nuclear Chemistry Research Division, Korea Atomic Energy Research Institute, 989-111 Daedeok daero, Yuseong-gu, Daejeon, 34057, Republic of Korea a r t i c l e i n f o a b s t r a c t Article history: As a part of evaluating the volatility of iodide ions subjected to gamma irradiation, I2 evaporation ex- Received 13 November 2016 periments were performed with I2 and Ie mixed solutions in the temperature range 26e80 C in an open, Received in revised form well-ventilated space. The evaporation of I2 was observed to follow primarily first order kinetics, 26 June 2017 depending on the I2 concentration. The evaporation rate constant increased rapidly with increase in Accepted 21 July 2017 Available online 12 August 2017 temperature. The presence of Ie slightly reduced the evaporation rate of I2 by forming relatively stable I 3. The effect of Cle at 1690 . Yeon, . Jung / Nuclear Engineering and Technology 49 (2017) 1689e1695 controlled in the range 26e80 C by a water bath. The airflow rate measured by the air velocity meter (TSI Velocicalc 8346, TSI Inc., Shoreview (MN), USA) at six points of evaporation vessels was in the range ± m/s. This flow rate was the maximum airflow of the fume hood, and was not determined from consideration of any reactor building condition. All I2 evaporation experiments were carried out in the same fume hood. The schematic diagram of the evaporation .

TỪ KHÓA LIÊN QUAN
TÀI LIỆU MỚI ĐĂNG
34    212    1    28-04-2024
46    187    0    28-04-2024
8    176    0    28-04-2024
10    157    0    28-04-2024
15    185    0    28-04-2024
10    118    0    28-04-2024
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.