TAILIEUCHUNG - Báo cáo khoa học: " Comparison of T2 and FLAIR imaging for target delineation in high grade gliomas"

Tuyển tập các báo cáo nghiên cứu về y học được đăng trên tạp chí y học Radiation Oncology cung cấp cho các bạn kiến thức về ngành y đề tài: " Comparison of T2 and FLAIR imaging for target delineation in high grade gliomas. | Stall et al. Radiation Oncology 2010 5 5 http content 5 1 5 RADIATION ONCOLOGY RESEARCH Open Access Comparison of T2 and FLAIR imaging for target delineation in high grade gliomas Bronwyn Stall Leor Zach Holly Ning John Ondos Barbara Arora Uma Shankavaram Robert W Miller Deborah Citrin Kevin Camphausen Abstract Background FLAIR and T2 weighted MRIs are used based on institutional preference to delineate high grade gliomas and surrounding edema for radiation treatment planning. Although these sequences have inherent physical differences there is limited data on the clinical and dosimetric impact of using either or both sequences. Methods 40 patients with high grade gliomas consecutively treated between 2002 and 2008 of which 32 had pretreatment MRIs with T1 T2 and FLAIR available for review were selected for this study. These MRIs were fused with the treatment planning CT. Normal structures clinical tumor volume CTV and planning tumor volume PTV were then defined on the T2 and FLAIR sequences. A Venn diagram analysis was performed for each pair of tumor volumes as well as a fractional component analysis to assess the contribution of each sequence to the union volume. For each patient the tumor volumes were compared in terms of total volume in cubic centimeters as well as anatomic location using a discordance index. The overlap of the tumor volumes with critical structures was calculated as a measure of predicted toxicity. For patients with MRI documented failures the tumor volumes obtained using the different sequences were compared with the recurrent gross tumor volume rGTV . Results The FLAIR CTVs and PTVs were significantly larger than the T2 CTVs and PTVs p and p respectively . Based on the discordance index the abnormality identified using the different sequences also differed in location. Fractional component analysis showed that the intersection of the tumor volumes as defined on both T2 and FLAIR defined the majority of the .

TÀI LIỆU LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.